ZLB(Q), HLB(Q) Vertical Half (Full) Adjustment Axial/Mixed-Flow Pumps

AP1000Residual Heat Removal Pumps
Range of head: (m)
Range of head: ~
m Range of quantity(m3/h)
Range of quantity: ~m3/h
An AP1000 normal residual heat removal pump - one of the main devices in a normal residual heat removal system (RNS) in an auxiliary plant of an AP1000 nuclear power plant, has the following main features:
It extracts the heat generated at shutdown of a reactor coolant system. After the start-up of an automatic pressure system (ADS), it provides low pressure replenishment water from the feeding tank of a spent fuel pool cooling system (SFS) to RCS.
When needed it discharges the residual heat from refuelling water tank built in the containment.
After an accident it provides a long-term refuelling channel to RCS
Other features: shutdown purification, low temperature overpressure protection, spent fuel pool cooling
An AP1000 normal residual heat removal pump is a main device in a normal residual heat removal system (RNS) in an auxiliary plant of an AP1000 nuclear power plant
Quantity of flow 364.08 m3/h
Head 103.6~115.8m
NPSH 2.65 m
Structural features:
Vertically Mounted PumpsUnder hot conditions, vertical pumps suppress upward conduction of heatThe compact overall structure meet the enveloping size requirements specified for the R&D task Rapid overhaul of nuclear pumpBalanced axial forceprevention of possible damage from cavitation in case of air included at inlet
Head 103.6~115.8m
NPSH 2.65 m
Structural features:
Vertically Mounted PumpsUnder hot conditions, vertical pumps suppress upward conduction of heatThe compact overall structure meet the enveloping size requirements specified for the R&D task Rapid overhaul of nuclear pumpBalanced axial forceprevention of possible damage from cavitation in case of air included at inlet
Design pressure:6.21MPa(g)
Design temperature:215.6℃
Specification:ASME BPVC-Ⅲ-1 ND-3400
Design temperature:215.6℃
Specification:ASME BPVC-Ⅲ-1 ND-3400